Toxic Gas Leak Detector 8081


Specialty Gases and Equipment
Your #1 Gas Supplier

(514) 956-7503

Toxic Gas Leak Detector
Model 8081

Description



Matheson's PortaSens Series of detectors provide compound specific leak detection of a wide variety of toxic gases and chemicals. Choose from twenty-three available sensors to suit your particular application. Each is optimized to provide maximum sensitivity with minimum interference from other gases.

The
PortaSens is extremely useful for locating gas leakage from process piping, tubing, pumps, valves, storage cylinders or any other vessel containing toxic gas. It will also accurately measure ambient concentrations in confined spaces or open areas. The detachable sample inlet extension wand allows samples to be drawn from the precise spot being tested. A durable, waterproof casing protects the detector from harsh environments.

An internal miniature pump, which delivers a positive and constant sample flow, provides a sampling advantage over slower diffusion based units. A compact sensing manifold further enhances rapid response times.

A backlit LCD provides a clear, easy-to-read gas concentration readout in any ambient lighting condition. Two user-adjustable alarms give visual and audible indications of alarm conditions. Low flow and low battery alarms are also provided.

Power is supplied by a rechargeable NiCad battery in the handle, which enables operation for 12 hours at 20ºC or 8 hours at 0ºC. An LED provides positive charge indication.

An intrinsically safe circuit design allows use of the PortaSens almost anywhere. An internal RFI coating shields sensitive electronics from interference.
Each PortaSens Toxic Gas Leak Detector is supplied in its own padded storage case. Also included in the case is a battery charger, a detachable sampling extension wand and a wall mounting bracket for those applications requiring the detector to be close at hand and ready for use.

Specifications
Detection Principle: Electrochemical sensor
Sampling Pump: Miniature rotary vane, 200 ccm nominal
Power: Rechargeable NiCad batteries 120/220VAC
50/60Hz charger
Operating Time: 12 hours at 68ºF (20ºC) with full charge
8 hours at 32ºF (0ºC) with full charge
Range/Resolution: See "Ordering Information" table below
Sensitivity: Approximately 5% of full scale
Repeatability: +/-3%
Linearity: +/-2%
Electronics: Designed to comply with intrinsic safety standards
Alarms: Two user-adjustable concentration alarms, low flow and low battery alarms
Size (LxWxH): 3" x 3" x 8" (7.6cm x 7.6cm x 20.3cm)
Weight: 11 ounces (300 grams)
Shipping Weight: 1 lb (450 grams)
Warranty: One year



Cross Sensitivity Table Sensor Type

Sensor Type

  NH3 CI2* HF HCl HCN H2S SO2 CO H2 O2 NO NO2 Hydride SiH4 COCl2
    NH3 N -0.05 N 0.1 N N N N N N N N N N
I CO 0.01 N N 0.005 N N N 0.1 N N 0.001 N N N
N H2 0.15 N N 0.01 N 0.005 0.005 0.1 N 0.001 0.001 0.001 0.001 N
T NO N N N 0.7 0.01 0.1 0.04 0.1 N N N N N -0.1
E O2 ** N ** ** N ** ** ** ** ** ** ** ** N
R CI2* -0.2 1 N -1 N -0.1 N N *** N 0.5 N N 0.2
F HCl N N 0.5 N N N N N N N -0.3 N N 0.1
E HCN 0.05 -0.08 -0.1 0.01 N 0.15 0.1 N N N 0.07 N N 0.5
R HF N N N N N N N N N N N N N N
I H2S 2 -0.1 -0.3 3 0.5 N N N N N -2.5 N N N
N NO2 -0.5 0.4 0.2 0.2 0.04 0.01 0.8 N N N N N N -1
G SO2 N -0.01 1 0.5 1 0.1 N N N N -1 N N 1
  Hydride 0.5 N N 0.7 1.5 0.1 2 N N N 1 -2 1 N
G SiH4 N N N 0.7 1.5 0.1 2 N N N 1 -2 1 N
A CO2 N N N N N N N N N **** N N N N N
S CH4 N N N N N N N N N N N N N N N
    CH3SH 0.7 -0.04 -0.1 1 0.2 0.3 N N N N N -0.8 N N N
    C2H2 0.03 N N N N 0.01 0.02 0.1 0.01 N 0.05 N 0.005 0.005 N
    C2H4 N N N N N N N 0.1 0.01 N N N N N N
    C2H6O 0.01 N N 0.02 N 0.01 0.05 N N N 0.001 0.001 0.01 0.01 N

N = No interference
Cross sensitivity data was developed by exposure of sensors to gas concentrations below 100 ppm. Sensors may show either transient or continuous responses different from those listed above, if exposed to very high concentrations of a gas. The values shown are the equivalent signal generated by the sensors when exposed to 1 ppm of the indicated gas. For instance, exposure of a chlorine (oxidant) sensor to 1 ppm of nitrogen dioxide would produce a sensor signal equivalent to 0.4 ppm CI2.
* Data shown for the chlorine sensor refers to the sensor used for bromine, chlorine, chloride dioxide, fluorine or ozone.
** Indicates a 3 electrode sensor that requires a minimum of 2% oxygen for proper operation.
*** Oxygen sensors will respond to halogen gases at % levels, but are unaffected by low ppm levels.
**** Oxygen sensor response will be affected by % levels of CO2, but is unaffected by low ppm levels.

Ordering Information

 

Model Description
8081-XX PortaSens Toxic Gas Leak Detector, complete with 120VAC charger, NiCad battery, detachable sampling extension wand, wall mounting bracket and padded storage case. Specify suffix XX for gas desired as listed below.
8082-XX Same as 8081 except with 220VAC charger. Specify suffix XX for gas desired as listed below.
8080-01 Cigarette lighter charger adapter.
8080-02 Audible horn alarm headset.

Model No.
Suffix XX

Gas

Range
15
Ammonia 0-200 ppm
28
Arsine 0-1000 ppb
10
Bromine 0-2 ppm
16
Carbon Monoxide 0-200 ppm
11
Chlorine 0-10 ppm
12
Chlorine Dioxide 0-2 ppm
29
Diborane 0-1000 ppb
13
Fluorine 0-2 ppm
30
Germane 0-1000 ppb
18
Hydrogen 0-2000 ppm
21
Hydrogen Chloride 0-20 ppm
22
Hydrogen Cyanide 0-20 ppm
23
Hydrogen Fluoride 0-20 ppm
31
Hydrogen Selenide 0-1000 ppb
24
Hydrogen Sulfide 0-50 ppm
25
Nitric Oxide 0-200 ppm
26
Nitrogen Dioxide 0-20 ppm
19
Oxygen 0-25%
14
Ozone 0-2 ppm
20
Phosgene 0-2 ppm
32
Phosphine 0-1000 ppb
33
Silane 0-20 ppm
27
Sulfur Dioxide 0-20 ppm
 