| Specifications
for 8086 Carbon Dioxide Monitor |
| Operating
Principle: |
Non-disperse
infrared (NDIR) |
| Sampling
Mode: |
Diffusion |
| Power: |
12VDC
via 120VAC/60Hz adapter or internal rechargeable battery |
| Battery
Operation Time: |
1
hour |
| Measurement
Range: |
0-1999
ppm; LCD readout |
| Accuracy: |
±5%
reading or ±50 ppm |
| Response
Time: |
<
20 seconds |
| Repeatability: |
±20
ppm |
| Maximum
Drift:: |
±100
color="ffffff">Alarm Range: |
User-adjustable
between 0-1999ppm |
| Operating
Temperature: |
32-122ºF
(0-50ºC) |
| Humidity
Range: |
5-95%
RH non-condensing |
| Output: |
0-2VDC
linear |
| Dimensions
(LxWxH): |
7"x3.5"x3"
(17.8cmx8.9cmx7.6cm) |
| Weight: |
20
ounces (567 grams) |
| Warranty: |
1
year |
Specifications for 8086R Data Logger |
| Power: |
12VDC
via 120VAC/60Hz adapter |
| Number
of Channels: |
Four |
| Input
Range: |
0-2.5/5.0VDC,
auto-ranging |
| Output: |
RS
232 interface to PC |
| Operating
Temperature: |
32-122ºF
(0-50ºC) |
| Humidity
Range: |
5-95%
RH non-condensing |
| Dimensions
(LxWxH): |
5.5"x3.75"x1.25"
(14cmx9.5cmx3.2cm) |
| Weight: |
4
ounces (114 grams) |
| Warranty |
1
year |
Specifications for 8086S VEMS
Includes 8086 & 8086R (see above for
specifications) |
| Power
Bag: |
12VDC
via 120VAC/60Hz adapter |
| Operation
Time: |
Up
to 12 hour operation
8-10 hours recharging time |
| Dimensions
(LxWxH): |
11"x8"x6"
(28cmx20.3cmx15.3cm) |
| Weight: |
10
lbs (4.54 kg) |
| Warranty: |
1
year |
| VG
Graphing Software: |
IBM