Combustible Gas Detector


Specialty Gases and Equipment
Your #1 Gas Supplier

(514) 956-7503

Combustible Gas Detector
Model 8059

Description
Matheson's Model 8059 Combustible Gas Detector is a rugged, portable instrument designed for monitoring combustible gas levels in ambient air. Weighing just 5.3 ounces, this compact unit is small enough to fit into a shirt pocket, or it can conveniently be worn on the belt. A two-stage audible and visual alarm provides early warning of potentially explosive conditions.
The Model 8059 continuously samples the air by diffusion for combustible gases and vapors. Calibrated on methane, the unit sounds a pulsating audible alarm with flashing LED at 10% of the Lower Explosive Limit (LEL), and a continuous audible alarm with steady LED at 25% LEL. The Model 8059 also provides 1st and 2nd-stage alarms for hydrogen (10% and 30% LEL), propane (15% and 40% LEL) and ethylene (15% and 40% LEL).

Gases Detected
Although calibrated on methane, the Model 8059 will detect virtually any combustible gas. The levels at which the alarms will activate depends upon the Lower Explosive Limit for the particular gas being detected. The Model 8059 has been shown to automatically activate 1st and 2nd stage alarms for the following gases.

Gas

1st stage alarm 2nd stage alarm
Methane 10% LEL 25% LEL
Hydrogen 10% LEL 30% LEL
Propane 15% LEL 40% LEL
Ethylene 15% LEL 40% LEL

Principle of Operation
The Model 8059 utilizes an explosion-proof catalytic combustion type sensor, with intrinsically safe electronic circuitry. The sensor consists of a coiled platinum filament coated with a platinum catalyst. When a combustible gas or vapor contacts the sensor, the gas is oxidized and the temperature of the platinum coil increases. This results in a proportional change in the resistance of the platinum filament. Gas concentration is then measured as a voltage change in a wheatstone bridge circuit. The circuit also utilizes a temperature compensation element to correct for ambient temperature changes.

Specifications
Detection Principle: Catalytic combustion sensor
Power Source: 4 x Size AA NiCad batteries (remote charger included)
Operating Time: Up to 4 hours with full charge (Alkaline batteries, not included, will provide up to 10 hours continuous operation)
Recharging Time: 14 hours from a fully discharged state
Alarm Settings: Methane: 10% and 25% LEL
Hydrogen: 10% and 30% LEL
Propane: 15% and 40% LEL
Ethylene: 15% and 40% LEL
Alarm characteristics: 1st stage: Pulsating audible tone; Flashing red LED
2nd stage: Continuous audible tone; Steady red LED
Response Time: 1st stage: 3-5 seconds
2nd stage: 10-20 seconds
Temperature Range: -10°C to 40°C (14-104°F)
Low Battery Indicator: Steady tone; flashing green LED
Dimensions: 2.5W x 3.4H x 1D (inches)(65mm x 85mm x 25mm)
Weight: 5.3 ounces (150g)
Warranty: One year

Ordering Information
Model Description
8059 Combustible gas detector with factory set two-stage alarm, leather case with belt loop, NiCad batteries (4), remote 115 VAC charger, test gas vial.
8059-220 Same as 8059 with 220 VAC charger.
8059-01 Replacement test gas vial.
8059-02 Replacement protective case.
8501 Replacement 115 VAC charger.
8502 Replacement 220 VAC charger.
For more information, request Matheson Tech-Brief TB-239.
 