Oxygen Deficiency Monitors


Specialty Gases and Equipment

(514) 956-7503

Oxygen Deficiency Monitors
Model 8060, Model 8061

Description
Matheson's Oxygen Deficiency Monitors are compact, portable instruments designed for the continuous monitoring of ambient oxygen levels. A large LCD digital readout clearly displays the oxygen concentration at all times. A pulsating audible alarm sounds when the level falls below 19.5 percent.
Two versions are available. The Model 8061 is equipped with a 16 foot cable on a spool connecting the instrument to the sensor, making it ideal for testing manholes, tanks, bilges, silos, etc. The Model 8060 has the sensor at the end of an extendable 3 foot coiled cable. In both models, the sensor attaches easily to the top of the instrument for hands-free use.
Both the Model 8060 and 8061 can be used to test the oxygen level in a confined area prior to entering, or, conveniently worn on the belt or over the shoulder (both belt loop and shoulder strap are provided), they serve as a personal monitor anywhere the danger of oxygen deficiency exists.

Principle of Operation
The sensor is a small, leakproof galvanic cell that plugs into a rugged protective holder. The galvanic cell consists of a noble metal electrode, a base metal electrode, and an electrolyte in aqueous solution. A specially designed diaphragm membrane prevents the evaporation of water from the cell, providing for a long sensor lifetime and eliminating the need to periodically replenish the water.
A potential difference exists between the two electrodes. In the presence of oxygen, current flows from the noble metal electrode to the base metal electrode:
Noble metal: O2 + 2H2O + 4e- 4OH-
Base Metal: 2Pb 2Pb ++ + 4e-
The output of the cell is proportional to the oxygen concentration, with a virtually linear relationship through the entire range of the instrument.
Also, since the current generated in a galvanic cell is affected by temperature, a thermistor is utilized to compensate for ambient temperature changes.

Specifications
Detection Principle: Galvanic cell
Power Source: 2 x size AA rechargeable NiCad batteries (remote charger also included)
Operating Time: Up to 20 hours with full charge
Recharging Time: 14 hours from a fully discharged state
Measuring Range: 0-40 vol %
Alarm: Preset to 19.5% Pulsating audible tone
Indication Accuracy: +/- 3% of O2 concentration
Response Time: 2-4 seconds
Temperature Range: 0-45°C (32-113°F)
Pressure Range: Up to 2 atm.
Low Battery Indicator: Steady audible tone
Dimensions: Model 8060: 4.7H x 2.6W x 1.1D (inches) (120 mm x 66 mm x 29 mm)
Model 8061: 6.7H x 2.6W x 1.1D (inches) (170 mm x 66 mm x 29 mm)
Weight: Model 8060: 8.8 oz (250g)
Model 8061: 10.6 oz (300g)
Expected Sensor Life: 18-24 months
Warranty: 1 Year

Ordering Information
Model No Description
8060 Oxygen deficiency monitor with 3 foot coiled cable connecting sensor to instrument, carrying case with belt loop and shoulder strap, NiCad batteries (2), remote 115VAC charger
8061 Same as Model 8060 with 16 foot non-coiled sensor cable.
8060-220 Same as 8060 with 220VAC charger
8061-220 Same as 8061 with 220VAC charger
8062-01 Replacement sensor for either 8060 or 8061 (hermetically sealed package).
8501 Replacement 115VAC charger for either model
8502 Replacement 220VAC charger for either model

For more information, request Matheson Tech-Brief TB-240.

 