Compressed
Breathing Air Analysis Kit
Model 8014BAK |
| Description |
 |
The Matheson Model
8014BAK is an on-line analysis kit for ensuring the quality of
compressed breathing air. It quickly and easily measures the
levels of carbon monoxide, carbon dioxide, oil mist, water
vapor, and oxygen. |
| Unlike other methods,
there is no need to take a grab sample and analyze it off line;
the 8014BAK is designed to connect directly to the compressed
breathing air source. It is available with a choice of three
connections--CGA 346, CGA 347, and 1/4" NPT Female. |
| It is very important
that the correct connection type be selected to match the
application: |
| The Model 8014BAK-01 is
fitted with a CGA 346 connection, and is rated for inlet
pressures of 0-3000 psig. This model should be selected for
analyzing compressed air in U.S. D.O.T. approved cylinders with
a Stamped Service Pressure in the range of 0-3000 psig. |
| The Model
8014BAK-03 is fitted with a CGA 347 connection, and is rated for
inlet pressures of 3001-5500 psig. This model should be selected
for analyzing compressed air in U.S. D.O.T. approved cylinders
with a Stamped Service Pressure in the range of 3001-5500 psig. |
| The Model
8014 BAK-02 is fitted with a 1/4" NPT Female connection,
and is rated for inlet pressures of 0-400 psig. This model
should be selected for analyzing compressed air from
non-cylinder sources having pressures no greater than 400 psig. |
| CAUTION:
Adapters must not be used which connect a high pressure source
to equipment rated at a lower pressure. |
| Some Typical
Applications |
| The Model 8014BAK is
ideal for anyone involved with the filling, generating, or usage
of compressed breathing air. It has been proven through use in a
variety of industries and applications. |
- Emergency air
packs/respirators
- Fire
departments/rescue squads
- Scuba/diving
- Hazardous waste
cleanup
|
| Components
Measured |
Range |
Sampling
Time |
| Carbon
Monoxide |
5-100
ppm |
2
min. |
| Carbon
Dioxide |
100-3000
ppm |
2
min. |
| Oil
Mist (Hydrocarbon) |
0.3-5
mg/m3 |
25
min. |
| Water
Vapor |
20-160
mg/m3 |
1
min. |
| Oxygen |
2-24% |
1
min. |
| Principle
of Operation |
 |
The Model 8014BAK system
is essentially comprised of a pressure regulator, flowmeter, and
a variety of detector tubes. |
| In
operation, measurements are made by passing the breathing air
through each detector tube at a specified flow rate, pressure,
and time interval. Each detector tube is formulated with a high
purity reagent which absorbs and reacts with the component being
measured. This causes a colorimetric stain whose length is
directly proportional to the amount of component in the
breathing air. Its concentration can be read directly from the
scale printed on each tube. |
| Ordering
Information |
| Model |
Description |
| 8014BAK-01 |
Compressed
breathing air analysis kit, complete with CGA 346 connection,
regulator, flowmeter, tube connector, tube tip cutter, timer,
wrench, and carrying case. No detector tubes included. |
| 8014BAK-02 |
Same
as above except with 1/4 NPT connection |
| 8014BAK-03 |
Same
as above except with CGA 347 connection |
| 8014-600SP |
Carbon
monoxide detector tubes* |
| 8014-601SP |
Carbon
dioxide detector tubes* |
| 8014-602SP |
Oil
mist hydrocarbon detector tubes* |
| 8014-603SP |
Water
vapor detector tubes* |
| 8014-604SP |
Oxygen
detector tubes* |
| 8014-002 |
Replacement
rubber tube connector (pkg 6) |
| *1
box containing 10 detector tubes |
| For