Qualitative
Analysis Tubes and HazMat Kit
Models 8070, 8075 |
| Description |
 |
Matheson's Qualitative
Detector Tubes provide fast on-the-spot identification of
unknown gases and vapors. There is no need for cumbersome grab
samples, time delayed laboratory analyses, expensive analytical
instrumentation or complex decision-tree matrix approaches. And
since calibration, electricity and battery charging are not
necessary, the tubes are always ready for immediate use. |
| Two types of tubes are
available. Model 8014-186B identifies a broad range of organic
compounds, such as gasoline, alcohols, hydrocarbons, etc. Model
8014-131 identifies inorganic compounds, such as carbon
monoxide, sulfur dioxide, chlorine, etc. Typically, both models
are used in concert, to assure detection of both organic and
inorganic compounds. |
| Principle
of Operation |
 |
In operation, Matheson's
Qualitative Tubes are used in the same way as conventional
detector tubes. That is, the high precision Matheson-Kitagawa
pump, Model 8014-400A, is used to draw the sample air through
the tubes. |
| However, unlike
conventional tubes which are "length of stain'' providing
quantitative measurements, these tubes are comprised of several
sections. Each section contains a unique, high purity blend of
reagents that will absorb and react with a particular gas or
vapor, or family of gases and vapors. The resulting reaction
causes a color change. The unknown gas or vapor is determined by
which section(s) changed color, and to what color they
changed to. |
| Model 8014-131 is used
to detect inorganic compounds and consists of 5 sections, labeled
"A'' to "E''. Only one tube is needed to
provide a complete analysis for inorganic. |
| Model
8014-186B is used to detect organic compounds and consists of 4
sections, labeled "A'' to "D''. Because of the
extensive number of detectable organic compounds, two tubes are
required for a complete analysis. One tube is used for "A''
side sampling (section A closest to pump), and is followed by a
second, fresh tube for "D'' side sampling (section D
closest to pump). The combined results are used to identify
unknown substances. |
| Compounds
Detected and Detectable Limits (parts-per-million) |
Inorganic Tube
Model 8014-131 |
| Acetic Acid (15) |
Hydrogen
Chloride (20) |
| Acetylene (10) |
Hydrogen Sulfide
(10) |
| Ammonia
(5) |
Methyl
Mercaptan (10) |
| Amines
(5) |
Nitrogen
Dioxide (5) |
| Carbon
Monoxide (10) |
Phosphine
(2) |
| Chlorine
(5) |
Sulfur
Dioxide (10) |
|
 |
 |
 |
 |
| Ammonia |
Butane |
Carbon Monoxide |
Hydrogen Sulfide |
Organic Tube
Model 8014-186B |
| Acetaldehyde (100) |
Heptane (10) |
| Acetone (500) |
Hexane (10) |
| Acetylene (100) |
Isopropyl Alcohol
(500) |
| Aniline (50) |
Kerosene (0.1
mg/l) |
| Benzene (100) |
Methyl Alcohol
(100) |
| Butadiene (1000) |
Methyl Ethyl
Ketone (100) |
| Butane (10) |
Methyl Isobutyl
Ketone (100) |
| 1-Butanol (100) |
Methyl Mercaptan
(20) |
| Butyl Acetate
(100) |
Pentane (10) |
| Carbon Disulfide
(100) |
Phenol (10) |
| Cresol (20) |
Propane (100) |
| Ethyl Acetate
(500) |
Styrene (100) |
| Ethylamine (100) |
Tetrachloroethylene
(100) |
| Ethyl Benzene
(400) |
Tetrahydrofuran
(100) |
| Ethyl Cellosolve
(100) |
Toluene (200) |
| Ethylene (10) |
Trichloroethane
(1000) |
| Ethylene Oxide
(100) |
Trichloroethylene
(1000) |
| Formaldehyde (10) |
Vinyl Chloride
(10) |
| Gasoline (0.1
mg/l) |
Xylene (1000) |
|
| Ordering
Information
|
| Model |
Description |
| 8014-131 |
Inorganic
gas detector tubes, 10/box |
| 8014-186B |
Organic
gas detector tubes, 10/box |
| 8070 |
Basic
Qualitative Analysis Kit, complete with 8014-400A sampling pump,
maintenance items, 1 box 8014-131 inorganic tubes, 2 boxes
8014-186B Organic tubes, and hard shell carrying case with
shoulder strap |
| 8075 |
Deluxe
HazMat Kit, complete with 8014-400A sampling pump, maintenance
items, 5 boxes 8014-131 Inorganic tubes, 10 boxes 8014-186B
Organic tubes, 8014-300K Air Flow Indicator Kit, 8014-018 ten
meter extension sampling hose, and hard shell carrying case,
with room to add up to 15 boxes of conventional detector tubes |
| 8014-017 |
5
meter extension sampling hose |
| 8014-018 |
10
meter extension sampling hose |
| 8014-300 |
Air
flow indicator tubes, 10/box |
| 8014-300K |
Air
flow indicator kit - with aspirator bulb, case, and one box
8014-300 tubes |
|
|