| Description |
| NAME: |
OXYGEN |
| FORMULA: |
O2 |
| Gas Data |
| MOLECULAR
WEIGHT: |
31.999 |
| DENSITY: |
1.309 kg/m3 @
25º, 101.325 kPa |
| DENSITY: |
0.0817 lb/ft3
@ 77ºF, 14.696 psi |
| SPECIFIC
VOLUME: |
0.7639 m3/kg
@ 25º, 101.325 kPa |
| SPECIFIC
VOLUME: |
12.239 ft3/lb
@ 77ºF, 14.696 psi |
| Shipping
Information |
| CAS
NUMBER: |
7782-44-7 |
| I.D.
NUMBER: |
UN 1072 |
| DOT
PROPER NAME: |
OXYGEN, COMPRESSED |
| TC PROPER
NAME: |
OXYGEN, COMPRESSED |
| HAZARD
CLASS: |
2.2 |
| LABEL: |
NONFLAMMABLE GAS,
OXIDIZER |
| Cylinder
Specifications |
| Cylinder
Size |
Valve
Outlet CGA No. |
Pressure
psig @ 70F |
Pressure
kPa @ 21.1C |
Approximate
Ship Weights |
| lbs |
kgs |
| 1L |
540 |
2,200 |
15,180 |
173 |
79 |
| 1A |
540 |
2,200 |
15,180 |
153 |
70 |
| 2 |
540 |
1,600 |
11,040 |
80 |
37 |
| 3 |
540 |
1,600 |
11,040 |
41 |
19 |
| 6 |
540 |
1,585 |
10,937 |
20 |
9 |
| 7B |
540 |
1,650 |
11,385 |
6 |
3 |
| 7A |
540 |
825 |
5,693 |
6 |
3 |
| 7 |
540 |
225 |
1,553 |
6 |
3 |
| LB |
170 |
1,600 |
13,800 |
6 |
3 |
| Gas
Grade Purity Specifications |
| Gas
Grade Purity Specifications |
Product
Code |
Cylinder
Size |
Content |
Equipment
Recommendations |
Model
No. |
| US |
Metric |
Oxygen,
Research Purity
99.998%
Guaranteed Specifications
Nitrogen < 5 ppm
Carbon Dioxide < 0.1 ppm
Carbon Monoxide < 0.1 ppm
Argon < 5 ppm
Krypton < 1 ppm
Nitrous Oxide < 2 ppm
THC < 0.1 ppm
Water < 1 ppm
|
1072071A |
1A |
249
ft3 |
7.05
m3 |
Dual
Stage Reg.
Single-Stage Reg.
Detector Tube
Leak Detector
Personal Monitor |
Series
3810-540
Series
3513-540
8014-159SC
8081
8060 |
| 10720702 |
2 |
70
ft3 |
1.98
m3 |
| 10720703 |
3 |
28
ft3 |
0.79
m3 |
| 10720704 |
4 |
11
ft3 |
0.39
m3 |
| 10720706 |
6 |
3.53
ft3 |
100
L |
| 1072077B |
7B |
1.76
ft3 |
50
L |
| 1072077A |
7A |
0.88
ft3 |
25
L |
| 10720707 |
7 |
0.25
ft3 |
7
L |
A
certificate of analysis is available upon request.
Caution: not for human consumption. |
| Gas
Grade Purity Specifications |
Product
Code |
Cylinder
Size |
Content |
Equipment
Recommendations |
Model
No. |
| US |
Metric |
Oxygen,
Matheson Purity (Not Available)
99.997%
Guaranteed Specifications
Nitrogen < 10 ppm
Argon < 15 ppm
Water < 1 ppm
Krypton < 10 ppm
THC < 0.5 ppm
Carbon Monoxide < 1 ppm
Carbon Dioxide < 1 ppm |
1072061L |
1L |
303
ft3 |
8.58
m3 |
Dual
Stage Reg.
Single-Stage Reg.
Flash Arrestor
Detector Tube
Leak Detector
Personal Monitor |
Series
3810-540
Series
3530-540
6103
8014-159SC
8081
8060 |
| 1072061A |
1A |
249
ft3 |
7.05
m3 |
| 10720602 |
2 |
70
ft3 |
1.98
m3 |
| 10720603 |
3 |
28
ft3 |
0.79
m3 |
| 10720604 |
4 |
11
ft3 |
0.39
m3 |
| 107206LB |
LB |
2.0
ft3 |
56
L |
A
certificate of analysis is available upon request.
Caution: not for human consumption. |
| Gas
Grade Purity Specifications |
Product
Code |
Cylinder
Size |
Content |
Equipment
Recommendations |
Model
No. |
| US |
Metric |
Oxygen,
Ultra High Purity
99.994%
Guaranteed Specifications
Argon < 35 ppm
Nitrogen < 15 ppm
THC < 0.5 ppm
Water < 2 ppm
Carbon Monoxide < 1 ppm
Carbon Dioxide < 1 ppm |
1072051L |
1L |
303
ft3 |
8.58
m3 |
Dual Stage Reg.
Single-Stage Reg.
Flash Arrestor
Detector Tube
Leak Detector
Personal Monitor
|
Series
3120-540
Series
3530-540
6103
8014-159SC
8081
8060- |
| 1072051A |
1A |
249
ft3 |
7.05
m3 |
| 10720502 |
2 |
70
ft3 |
1.98
m3 |
| 10720503 |
3 |
28
ft3 |
0.79
m3 |
| 10720504 |
4 |
11
ft3 |
0.39
m3 |
| 107205LB |
LB |
2.0
ft3 |
56
L |
A
lot analysis is available upon request. Please inquire for
individual cylinder analysis.
Caution: not for human consumption.
|
| Gas
Grade Purity Specifications |
Product
Code |
Cylinder
Size |
Content |
Equipment
Recommendations |
Model
No. |
| US |
Metric |
Oxygen,
Zero Gas
99.8%
THC as CH4
< 0.5 ppm |
1072031L |
1L |
303
ft3 |
8.58
m3 |
Dual
Stage Reg.
Single-Stage Reg.
Flash Arrestor
Detector Tube
Leak Detector
Personal Monitor |
Series
3120-540
Series
3530-540
6103
8014-159SC
8081
8060 |
| 1072031A |
1A |
249
ft3 |
7.05
m3 |
| 10720302 |
2 |
70
ft3 |
1.98
m3 |
| 10720303 |
3 |
28
ft3 |
0.79
m3 |
| 10720304 |
4 |
11
ft3 |
0.39
m3 |
| 107203LB |
LB |
2.0
ft3 |
56
L |
A
lot analysis will be provided with each cylinder. Please inquire
for individual cylinder analysis.
Caution: Not for human consumption. |
| Gas
Grade Purity Specifications |
Product
Code |
Cylinder
Size |
Content |
Equipment
Recommendations |
Model
No. |
| US |
Metric |
Oxygen,
Extra Dry
99.6% |
1072011A |
1A |
249
ft3 |
7.05
m3 |
Dual
Stage Reg.
Single-Stage Reg.
LB Regulator
Detector Tube
Leak Detector
Personal Monitor |
Series
3120-540
Series
3530-540
Series
3550-170
8014-159SC
8081
8060 |
| 10720102 |
2 |
70
ft3 |
1.98
m3 |
| 10720103 |
3 |
28
ft3 |
0.79
m3 |
| 10720104 |
4 |
11
ft3 |
0.39
m3 |
| 107201LB |
LB |
2.0
ft3 |
56
L |
A
certificate of conformance will be provided on request.
Caution: Not for human consumption. |
|